Water Tightness

PDF | Print

Glas Vision 3000 windows have been fully independently tested by ift Rosenheim in Germany (full test results are available on our downloads page) for Watertightness, i.e. the ability of the window system to resist water penetration to the internal face after spraying the window and then applying pressure to the external face of the window in set steps from zero up to 600Pa.

The sample windows were tested to EN 1027 : 2000-06 and the results are classified in accordance with EN 12208 : 1999-11.

BS 6375-1 : 2004 recommends a class 3A or 100Pa for most locations in the UK rising to class 5A or 200Pa for extreme conditions.

The performance levels achieved by the Vision 3000 product are well in excess of these requirements and, in the case of the tilt & turn and bottom hung casements, reached the maximum pressure able to be applied to a window (1050Pa) in the ift Rosenheim laboratories.

With the outstanding performance figures, you can be rest assured that the Vision 3000 product will be suitable for any almost any application, even for the most extreme conditions.
 

   

Performance
Vision 3000 Window Type No leakage at Rating to
EN 12208 : 1999-11
Side Hung open in 600Pa 9A
Fixed Light (min. sightline) 600Pa 9A
Fixed Light (dummy vent) 600Pa 9A
Bottom Hung open in 1050Pa (*) E1050
Tilt and Turn 1050Pa (*) E1050

• Tests carried out to EN 1027 : 2000-06 and are classified as EN 12208 : 1999-11.*

• * Maximum laboratory testable pressure (classified as E1050 for exceptional performance)

• Individual test results refer to individual window types and sizes.

• Refer to full test reports and Glas Technical for full details.